|About |Contact | Korean |

 

EChem News  Letter

e-mail address
Company Name
Country

Name


 

WBCS Software

 

*   32bit multi-tasking

*   Tool bar: quick access for easy operation

*   WYSIWYG graphics

*   User friendly software

 

*         Virtual control panel........

*  BCO(Button click operation); User can do any task  with just clicking the button:

*  Easy assignment of cycle test condition file to channel with combo box selection at anytime.

*  Synchronized change function of cycle test condition file for selected multiple channels.

*  Real time dual channel(V & I) strip chart display for selected channel or for all running channels with  time scrolling mode or whole window mode.

*  Status bar displays channel status.

*  Various task function: run, stop, suspend, moving step etc..

*  Spying the contents of test program which assigned to channel

*  Assign temperature, AuxV and CalcV channel on virtual control panel

 

 

*         Test Program

*  One stop test condition creation/modification

*  Parameter mixed input system

*  Unlimited number of test steps

*  Control values are voltage(CV), current(CC), power(CP), rest, C-rate,  I.

*  Step flow are defined by next step, Loop and cycle

*  Cut-off conditions can be set by;

time, voltage, current, dV/dt, dI/dt, percentage capacity(FCC, FCD, LCC, LCD), cycle time, capacity, -dV, power, temperature, Aux voltage, Calc voltage, dT/dt, Loop time, EocV

*  Data sampling condition by each step : time, dV/dt, dI/dt, dT/dt, dV2/dt

*  And/Or logic in cut-off condition setting

 

*         Menu Selection(Pre-defined techniques)

*  Lithium battery application mode menu

*  CC charging/discharging mode menu

 


*         Pulse Capability(GSM/CDMA application): Option

*  Parameter Input

 

Oscilloscope capture                        Pulse test data(option)

 

*         Simple Monitor

 

*   Real time display: time, voltage, current, channel status

*   channel status color display: charging, discharging, standby, idle, calibration

*   Always activated window(This widow does not hidden)

*   Can be located outside of main program window.

 

*         Detailed Monitor

*   displayed test data: status, running time, step number, cycle number,  step time, current range, current, voltage, capacity, power, energy, Aux V, Calc V, temp, cycle file name, data file name,  file size.

*   Detailed monitor type selection: All channels, running channels only, grouped channels

*   Activated character only for running channels.

 

*         Grouping

*   Classification/Grouping each channels by users purpose

*   Labeling each group by operator name, chemistries etc. Group monitoring available by this setting.

 

*         Graphics

*  Multiple plot formats

*  General Graph

*  Cycle Graph

*  Step Graph


 

User can define axis with specified parameters under each graph format.

 

*  General graph format

 

Current-Voltage vs. time graph            Current-voltage vs. cycle time graph

 

*  Cycle graph format

 charging capacity-discharging capacity vs. cycle number  graph

 

*  Real time plotting

 


*  Step graph format


 

                                                                                   dQ/dV vs. Voltage graph(EVS)

 

*  General Function of Graph

*   DQ/dV vs. Voltage

*   Voltage vs. charging time

*   Voltage vs. discharging time

*   Voltage vs. charging Capacity(discharging capacity)

*   Voltage vs. capacity etc.. Plot overlay: Max. 10 plot

*   Universal Graphics: Any combination of X,Y,Y1 axis parameters

*   Automatic updating plot with reloading button for running channel data

*   Automatic/Manual scale and polarity selection for each axis

*   Cross hair pointer by mouse click/arrow key displays coordinate values

*   Mouse zooming

*   Text insertion on graph

*   Copy to Clipboard  for usage in other application software

*   Slope calculation

*   Grid On/Off and dot/line selection

*   Parameter change without reloading the data file

*   Data set On/Off: Data can be visible or invisible by selecting/ deselecting the data set.

*   ASCII file conversion of graph data only

 

Voltage vs. charging-discharging time graph    Voltage vs. |charging-discharging capacity| graph

 

Cyclic voltammogram                                                             Tafel graph

 

*         Reporting

*   General data report

*   Cycle data report

*   Capacity data report

*   Step data report

*   Calibration data report

*   Test program report

*   Automatic documentation; running time, Test memo, operator name, weight, test I.D etc.

 

*         Calibration

 

 

 

 

 

 

 

 

 

 

*   4 points calibration for voltage and each current ranges

*   Check-out function with calibrated data for confirming accuracy

*   Calibrates a channel while other channels are running

*   To prevent wrong-calibration, error warning displays when error happens.

*   Linear calibration for + & - polarity with one procedure

*   Store & Backup calibration data

 

*         Filing

*   Create Potentiostat/Galvanostat mode or potentiostat mode test program file(Dual mode)

*   ASCII file conversion(TAB, comma, space delimited) of general data, cycle data, capacity data and step data

*   Maximum file size: 2GB

*   Split general data by cycle number

*   Max. Data file name: 15char + channel number(3digit)

 

*         Safety.

*   Double safety check: Automatically stop the test run if the voltage /current/ temperature exceed the hardware specification or safety  limit setting value on test program

*   Fail function: If the measurement value is different from control value, the test is stopped by fail check function in order to protect the cell and/or system failure.

*   Each channel has its own fuse to protect over current or voltage

*   While any channel is running, operator could not close the server program

*   Automatic cell mount detection

 

*         Misc

*   Closing function of all activated windows

*   Dual time input mode(9999sec or hh:mm:ss)

*   Independent server program

*   English version & Korean version available

 

*         System Requirement

*   Operating system: Windows2000/XP/Vista/7

*   Processor: Pentium4 or above

*   RAM: 512MB or above

*   VGA: 1024 x 768 or above

*   Interface: PCI bus or USB

*   Mouse

*   Printer: most printers/plotters supported by Windows. (Color printer/plotter recommended)