|About |Contact | Korean |

 

EChem News  Letter

e-mail address
Company Name
Country

Name


 

Mid Power type WBCS3000M2
Automatic Battery Charge/Discharge Test System

 

*         Application

*   Max. power: 100/200Watt per channel

*   Battery Test

*   Super capacitor Test

*   Fuel Cell Test

*   Electroplating,Electrosynthesis,Electrolysis

*   Pulse charge/discharge; option

*   Plug In channel Type

*   Various Safety protection

*   Other Electrochemical Experiment available

*   Universal Graphic function

*   And more & more …….

 

*         Feature

 

*   Potentiostat/galvanostat circuit

* No switching time (charging to discharging, discharging to charging)

* Analog feedback control to keep constant voltage & current

* Capability of electrochemical experiments by controlling voltage versus reference electrode for positive voltage polarity only.(For +/- voltage range application, choose WMPG series multichannel potentiostat/Galvanostat)

 

* High precision

* 16bit(0.0015% full scale) ADC, DAC

* 3 current ranges (automatic/manual selection)

* MOSFET type linear power supply circuit.

* Shield cell cable to prevent EMI noise

 

* Safety

* Unique “Fail check” function: Automatic stop when measured value is different from control value by battery failure or wrong cell connection etc. => To protect system and cell.

E.g. Control value: 1Amp Measured value: 500mA then automatic stop the channel

* System safety parameter: If the measured value is over system specification, Automatic stop the running channel

* User defined safety condition setting: User can input safety level following test cell’s chemistry.

* Automatic cell connection check: Before experiment, if the cell voltage value is near 0Volt, program gives the warning message for the operator to check the cell connection.

* If operator did press stop function button by mistake, confirmation message box appears.

* To prevent over current, poly-switch is located in each channel

* Watchdog function: Stop “running channel(s)” on communication Failure.

* While any channel is running, operator could not close the server program

* If main program was down by unstable operating system, independent server program keeps the experiment (control & data acquisition) without dead time.

 

* Maintenance & System expansion

*   Plug-In type channels

*   Power supply per 8channel

*   Easy expansion by adding plug in channel or by adding 8ch substation

*   Each channel has Poly switch instead of fuse.

 

*         Option

*   Auxiliary voltage & Temperature measurement

* User can assign any temperature input or auxiliary voltage input to single or multiple channel(s) data set by his/her demand.

* Customized auxiliary voltage range and temperature range is available.

 

* Current pulse Capability (GSM/CDMA application):

* Bi-polar current pulse available

* Max. 10 stages.

 

* Battery jigs

* Universal Jig

* Lithium polymer battery Jig

 

*         Mid power type Channel Power Limit

* Each channel’s maximum power is 100Watt or 200Watt (Power= Max. voltage x Max. current x 2)

* Max. current is 20Amp/channel

* Max. voltage can be selected within channel power limit

 

For higher power or lower current

*       Low current type WBCS3000L(Max. current: 10mA)

*       Standard power type WBCS3000S(Max 40Watt/channel)

*       High power type WBCS3000HP(>200Watt/channel)

Related Links

*       WBCS Software Introduction

*       WBCS Catalog Download

*       WBCS operation manual Download