WMPG Software 
Application
Electrochemical Voltage Spectroscopy(EVS)
Galvanic Intermitant time technique(GITT)
Tafel Plot
Potentiodynamic
Galvanodynamic
OCV measurement
Zero resistance Ammeter(option)
Linear polarization
Chrono-amperometry
Chrono-coulometry
Chrono-potentiometry
Square Wave Voltammetry (option)
User defined techniques
32bit multi-tasking
Tool bar: quick access
for easy operation
WYSIWYG graphics
User friendly software
Virtual control panel........
BCO(Button click operation); User can do any task with just clicking the button: NO MENU SELECTION
Easy assignment of cycle test condition file to channel with combo box selection at anytime.
Synchronized change function of cycle test condition file for selected multiple channels.
Real time dual channel(V & I) strip chart display for selected channel or for all running channels with time scrolling mode or whole window mode.
Status bar displays channel status.
Booking running channel stop function by time, cycle number, step etc.
Various task function: run, stop, suspend, moving step etc..
Spying the contents of test program which assigned to channel
Test Program
Multichannel Potentiostat/Galvanostat WMPG series
One stop test condition
creation/modification
Parameter mixed input system
Unlimited number of test steps
Control values are voltage, current, power, load, rest, C-rate, current scan, voltage scan, conditioning potential, voltage step, current step, rest conditioning, Last I, Last V, OCV.OcvScan
Step flow are defined by next step, Loop and cycle
Cut-off conditions can be set by;
time, voltage, current, dV/dt, dI/dt, percentage capacity(FCC, FCD, LCC, LCD), cycle time, capacity, -dV, power, temperature, Aux voltage, Calc voltage, dT/dt, OCVData sampling condition by each step : time, dV/dt, dI/dt, dT/dt, dV2/dt
And/Or logic in cut-off condition setting
Simple Monitor
Real time display:
time, voltage, current, channel status
channel status color display:
charging, discharging, standby, idle, calibration
Always activated window(This
widow does not hidden)
Can be located outside
of main program window.
Detailed Monitor
displayed test data: status, running time, step number, cycle number, step time, current range, current, voltage, capacity, power, energy, Aux V, Calc V, temp, cycle file name, data file name, file size.
Detailed monitor type selection: All channels, running channels only, grouped channels
Activated character only for running channels.
Grouping
Classification/Grouping
each channels by users purpose
Labeling each group by
operator name, chemistries etc.
Group monitoring available
by this setting.
Graphics
Multiple plot format
General graph
Plot overlay: Max. 10
plot
Universal Graphics: Any
combination of X,Y,Y1 axis parameters
Automatic updating plot
with reloading button for running channel data
Automatic/Manual scale
and polarity selection for each axis
Cross hair pointer by
mouse click/arrow key displays coordinate values
Mouse zooming
Text insertion on graph
Copy to Clipboard
for usage in other application software
Slope calculation
Grid On/Off and dot/line
selection
ASCII file conversion
of graph data only
Parameter change without
reloading the data file
Data set On/Off: Data
can be visible or invisible by selecting/ deselecting the data set.
Reporting
General data report
Cycle data report
Step data report
Capacity data report
Calibration data report
Test program report
Automatic documentation;
running time,Test memo, operator name, weight, test I.D etc.
Calibration
4 points calibration
for voltage and each current ranges
Check-out function with
calibrated data for confirming accuracy
Calibrates a channel while
other channels are running
To prevent mis-calibration,
error warning displays when error happens.
Linear calibration for
+ & - polarity with one procedure
Store & Backup calibration
data
Filing
Create Potentiostat/Galvanostat
mode or potentiostat mode test program file(Dual mode)
ASCII file conversion(TAB,comma,space
delimited) of general data, cycle data, capacity data and step data
Maximum file size: 2GB
Split general data by
cycle number
Max. Data file name: 15char
+ channel number(3digit)
Software UPS function
Function On/Off: User
can turn on/off this mode
When UPS function is activated,
any assignment on virtual control panel is memorized at closing the program.
Safety.
Double safety check: Automatically
stop the test run if the voltage /current/ temperature exceed the hardware
specification or saftey limit setting value on test program
Fail function: If the
measurement value is different from control value, the test is stopped
by fail check function in order to protect the cell and/or system failure.
Each channel has its own
fuse to protect over current or voltage
While any channel is running,
operator could not close the server program
Automatic cell mount detection
Misc
Closing function of all
activated windows
Dual time input mode(9999sec
or hh:mm:ss)
Independent server program
English version &
Korean version available
Inquiry: sales@wonatech.com